Hi,

 I have some Polaris data which I have been using with VMS GSAS, but I
wanted to use chemical constrains so I transferred the data (as an ASCII
file) to a PC. I tranferred two datasets: xray and neutrons, and PC GSAS
reads (and refines) successfully the xray dataset. I can plot the neutron
data with Rawplot, but when I tried to run a refinement, the
time-of-flight scale changed (and also the d-spacing). I checked the
diffractometer contants and they have the right values, and if I plot
again the rawdata with rawplot the scales are right. But in the
experimental file, the data range is 9.9999-13.0 instead of 4-18.5msec. I
created another experimental file and this time powpref cannot process the
neutron dataset. I got the message: run-time error M601:MATH-floating
point error:invalid. 

How can I transfer Polaris data into PC GSAS? Can I use in PC GSAS data 
with this format:                                                 
BANK    2 3118  780 RALF   128000       64   128064    0.00050 
ALT              
  128000 335561 1756  128064 335536 1879  128128 335618 1880  128192 
333237 1873
  128256 335231 1879  128320 335609 1880  128384 340373 1908  128449 
335324 1880

Thanks,

Paz Vaqueiro

E-mail:[EMAIL PROTECTED], [EMAIL PROTECTED]
Heriot-Watt University
Edinburgh, UK

Reply via email to