In comparing refinements with different powder datasets there is no "number of observations" in common usage and no 10:1 rule of thumb. Broadly, this means "crappy" data with a chemically unreasonable model can sometimes give much better figures of merit than a good structure with "good" data.

Sad, isn't it?

Jon


Von Dreele, Robert B. wrote:


Nandini,
I suggest you look at the paper "Rietveld refinement guidelines", J. Appl. Cryst. 
(1999) 32, 36-50.
Bob Von Dreele


-----Original Message----- From: Nandini Devi Radhamonyamma [mailto:[EMAIL PROTECTED] Sent: Thu 2/26/2004 8:38 AM To: [EMAIL PROTECTED]

Thank you.
In parallel with single crystal analysis, is there an
accepted limit for R(F2) or any other parameter like
Rexp to follow? I'm using synchrotron data.
nandini







Reply via email to