Dear Andrew,
You only need to constrain RM11 and RM33 to be the same for both phases; GSAS takes 
care of RM22 by symmetry.
Bob Von Dreele  


-----Original Message-----
From: Andrew Hector [mailto:[EMAIL PROTECTED]
Sent: Thu 3/25/2004 9:44 AM
To: [EMAIL PROTECTED]
 
I am trying to refine a magnetic structure in Cmma based on a tetragonal
nuclear cell.  To do this I need to constrain together the a and b
parameters.  I have been constraining the RM11 and RM22 terms to move
together, this keeps a and b the same but introduces a high level of
instability to the refinement, the fit slowly deteriorates in every cycle
whenever lattice parameters are refined.  The following message appears in
the lst file:

    2 Columns of the     4 Column matrix are 0.0

         Variable NoVarabl was not refined

         Variable NoVarabl was not refined



I'd appreciate anyone's thoughts on how to get around this.



Andrew Hector.





__________________________________
Dr Andrew L Hector
Royal Society University Research Fellow
School of Chemistry
University of Southampton, SO17 1BJ, UK








Reply via email to