Lakshminarasimhan Narayanan said:
> Dear All,
>
> I request you to clarify the following doubts that I have regarding
> refinement ( I am using FullProf program):
>
> 1.  While refining the x,y,z coordinates of an atom, the codes should be
> same for all three or different?
>

Different in most cases. Allthough, if the coordinates are related by
symmetry, like for example: if x=x1, y=x1+1/2, z=z1, x and y should have
the same code (can't check this right now, just how I remember it is).

> 2.  While refining the Boverall for the X-ray data, I am ending with a
> negative value, is it acceptable?
>

No. To help with that one really should have the data and pcr-file to look
 at. Try the refinement sequence as it is given in the help file (pdf) of
the latest FullProf version.

> 3.  For X-ray data, if there are 3-4 types of O atoms in the crystal
> structure, whether the Biso should be refined simultaneously by giving the
> same code number or individually refined by giving different code numbers.
>
>

Different codes. Different bonding environements can result in different
displacement parameters. On the other hand, it may be that oxygen Biso
refinement against X-ray data will not succeed anyhow, regardless how you
do the refinement.

-All the best!
  Markus

-- 
Markus Valkeap��, [EMAIL PROTECTED]
Inorganic Chemistry, G�teborg University
tel: +46 (0)31 772 2857; fax: +46 (0)31 772 2853
mail: Oorganisk kemi GU, SE-412 96 Gothenburg, Sweden


  • Help! Lakshminarasimhan Narayanan
    • Re: Help! Markus Valkeapää