bpa wrote: > I hope the "-R -u" settings are right - they are a bit cryptic so it may > take a few attempts to get right combination. > > > Code: -------------------- > > > -R -u [params] Resample, params = <recipe>:<flags>:<attenuation>:<precision>:<passband_end>:<stopband_start>:<phase_response>, > recipe = (v|h|m|l|q)(L|I|M)(s) [E|X], E = exception - resample only if native rate not supported, X = async - resample to max rate for device, otherwise to max sync rate > flags = num in hex, > attenuation = attenuation in dB to apply (default is -1db if not explicitly set), > precision = number of bits precision (NB. HQ = 20. VHQ = 28), > passband_end = number in percent (0dB pt. bandwidth to preserve. nyquist = 100%), > stopband_start = number in percent (Aliasing/imaging control. > passband_end), > phase_response = 0-100 (0 = minimum / 50 = linear / 100 = maximum) > > -------------------- > >
Bingo! Now resamples Qobuz to 24/96 and keeps CD quality untouched. You got the recipe right first time. Many thanks for your help! Nuno ------------------------------------------------------------------------ nunovi's Profile: http://forums.slimdevices.com/member.php?userid=18347 View this thread: http://forums.slimdevices.com/showthread.php?t=107980 _______________________________________________ ripping mailing list [email protected] http://lists.slimdevices.com/mailman/listinfo/ripping