Was dinking around on my newstalk with some upcoming programming changes
and I haven't quite perfected how to have Rivendell switch to network, and
pause and then switch back to local automation and play breaks with out it
getting mucked up with contact closures during the break retriggering the
break or other oddities.

Here' one of my typical segment macro carts

LC red The Jim Bohannon Show!
PE S1 3 1 090102!
SA 1 2 1!
GE 1 I 7 1!
GE 1 I 5 1!
PS 1!
SP 1000!



And I have my local break GPI firing this macro cart

SA 1 1 1!
SP 50!
SR 1 2 1!
SP 50!
PN 1!
SP 50!
GE 1 I 7 0!
GE 1 I 5 0!
LC red AM 1360 The Patriot!


It more or less works most of the time but I'm hoping someone has this
figured out to a science with a better solution.

Maybe a feature request would be the availability of pre-fab network
segment macro carts that just need the switcher channel and what GPI's to
enable during the segment plugged in?


Matthew A. Chambers, NR0Q

President, Wright County Outlaws ARC
_______________________________________________
Rivendell-dev mailing list
[email protected]
http://caspian.paravelsystems.com/mailman/listinfo/rivendell-dev