I finally upgraded to the Sage Digital Endec 3644 and was wondering to see if there was a way to trigger a RWT/Required Weekly Tests by a macros button. And I was also wondering if I could trigger delayed alerts by a separate macros button which would be for severe weather alerts, RMT/Required Monthly Tests.
On Sat, Mar 12, 2016 at 12:39 AM Chuck <[email protected]> wrote: > On Fri, 11 Mar 2016 08:03:24 -0500 > Ryan Kin <[email protected]> wrote > > > I'm planning on buying a Gorman Redlich CAP-Converter later on < > > Ooooh. We had a Gorman and it was the single piece of equipment that > failed most often in our air chain--at least twice a year. (Our Omnia > One did get fried by a power spike caused by a lightning hit, but we > have since installed some heavy-duty Eaton filtering.) Had to send the > Gorman back in just about yearly for service they said we could not > perform--which left us without EAS for weeks at a time. No loaner > provided. > > When the new changes came in, we switched to Sage, rather than get the > Gorman upgrades. Sage is tough to set up, and almost everyone we talked > to said that Sage had to help them (us, too), but once it was up and > running, not a single failure. What is that? 2 years now? > > Were I you, I would check with some Gorman owners before taking that > plunge. The ones we know around us all switched to Sage, too. > > --Chuck W. > >