I finally upgraded to the Sage Digital Endec 3644 and was wondering to see
if there was a way to trigger a RWT/Required Weekly Tests by a macros
button. And I was also wondering if I could trigger delayed alerts by a
separate macros button which would be for severe weather alerts,
RMT/Required Monthly Tests.

On Sat, Mar 12, 2016 at 12:39 AM Chuck <[email protected]> wrote:

> On Fri, 11 Mar 2016 08:03:24 -0500
> Ryan Kin <[email protected]> wrote
>
> > I'm planning on buying a Gorman Redlich CAP-Converter later on <
>
>   Ooooh.  We had a Gorman and it was the single piece of equipment that
> failed most often in our air chain--at least twice a year.  (Our Omnia
> One did get fried by a power spike caused by a lightning hit, but we
> have since installed some heavy-duty Eaton filtering.)  Had to send the
> Gorman back in just about yearly for service they said we could not
> perform--which left us without EAS for weeks at a time.  No loaner
> provided.
>
>   When the new changes came in, we switched to Sage, rather than get the
> Gorman upgrades.  Sage is tough to set up, and almost everyone we talked
> to said that Sage had to help them (us, too), but once it was up and
> running, not a single failure.  What is that? 2 years now?
>
>   Were I you, I would check with some Gorman owners before taking that
> plunge.  The ones we know around us all switched to Sage, too.
>
> --Chuck W.
>
>
_______________________________________________
Rivendell-dev mailing list
[email protected]
http://caspian.paravelsystems.com/mailman/listinfo/rivendell-dev