(this mail didn't go through earlier...trying to resend.. removing the screenshots for now....)
On Wed, Jun 23, 2010 at 3:39 AM, Thomas Friedrichsmeier <[email protected]> wrote: > On Tuesday 22 June 2010, Prasenjit Kapat wrote: >> When you find some time, here is some more information: >> this bug seems to be related to KDE 4.4.x series; see below. After some more goofing around, I think this may have something to do with the dual monitor setup. I am running the Lenovo T410 with an nvidia card and an external monitor connected in twinview using the binary nvidia driver. It doesn't matter, if KDE's composition is enabled/disabled. If I disconnect the external monitor and restart X with a modified xorg.conf (removing twiinview stuff) then I don't see this bug - although I haven't spent much time this way. Also, as I had mentioned earlier, this happens when there are no existing devices before any plotting cmd is called. A duplicated device does not have this bug. For example: Plot Beta probabilities. Check "Preview". Then duplicate the device (device 2 to 3). Set the original one active (dev.set(2)). Now, uncheck "Preview." - device 2 closes nicely. Call dev.off () once more, device 3 closes nicely as well. Is there some issue (or incompatible interaction with the dual-head setup) in .rk.do.call ("statOpenX11", ...) when dev.cur () == 1? It seems this bug was seen (on OSX) in 2007 (you may have seen this thread): http://tolstoy.newcastle.edu.au/R/e2/devel/07/05/3138.html Does Paul Murrell's reply help? >> > Ok, then here's an idea for a hack around the bug: Directly before the >> > "real" dev.off() add >> > .rk.lock.device <- TRUE >> > and >> > .rk.lock.device <- FALSE >> > directly after. In rk.screen.device add >> > if (exists (.rk.lock.device) && .rk.lock.device) return >> > at the start. >> >> Well, this didn't help :( Issue persists. > > Ok, turn those "<-" into "<<-", obviously. I would not be surprised, if this > has undesirable side-effects, but it should really have *some* effect on the > issue. It just baffles me, in spite of this hard return rule, two additional devices are still created!! The issue is deep inside somewhere else. > If it still does not, try > debug (rk.screen.device) > and inspect what's going on in there after calling dev.off(). (Although the > real mystery is why rk.screen.device() is getting called at all during > dev.off(). debug (rk.screen.device) behaves badly. The plot is displayed in a separate _native_ X11 window and rkward's device window is kept detached from it (see the two screenshots)! Anyway, that may be another issue! Doing debug (dev.off) shows: (A) the current device (2) is closed and (B) two new devices (3,4) are opened when .Internal (dev.off (.......)) gets called. Regards, -- Prasenjit ------------------------------------------------------------------------------ ThinkGeek and WIRED's GeekDad team up for the Ultimate GeekDad Father's Day Giveaway. ONE MASSIVE PRIZE to the lucky parental unit. See the prize list and enter to win: http://p.sf.net/sfu/thinkgeek-promo _______________________________________________ RKWard-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/rkward-devel