On Monday, March 12, 2012 09:53:00 am Quamis wrote:
> Se sa un server Dell PowerEdge SC440 care are 2 hdd-uri intern.
> De ceva timp tot apare in dmesg erori de genul
> 
> [Mar01 135142] mptbase: ioc0: RAID STATUS CHANGE for PhysDisk 0 id=1
> [Mar01 135142] mptbase: ioc0:   PhysDisk is now missing
> [Mar01 135142] mptbase: ioc0: RAID STATUS CHANGE for PhysDisk 0 id=1
> [Mar01 135142] mptbase: ioc0:   PhysDisk is now missing, out of sync
> [Mar01 135142] mptbase: ioc0: RAID STATUS CHANGE for VolumeID 0
> [Mar01 135142] mptbase: ioc0:   volume is now degraded, enabled
> [Mar01 135142]  end_device-4:1: mptsas: ioc0: removing sata device:
> fw_channel 0, fw_id 1, phy 1,sas_addr 0x1221000001000000
> [Mar01 135142]  phy-4:1: mptsas: ioc0: delete phy 1, phy-obj
> (0xffff880036506800)
> [Mar01 135142]  port-4:1: mptsas: ioc0: delete port 1, sas_addr
> (0x1221000001000000)
> [Mar01 135142] scsi target4:0:1: mptsas: ioc0: delete device:
> fw_channel 0, fw_id 1, phy 1, sas_addr 0x1221000001000000
> [Mar01 135219] mptbase: ioc0: RAID STATUS CHANGE for PhysDisk 0 id=1
> [Mar01 135219] mptbase: ioc0:   PhysDisk is now online, out of sync
> [Mar01 135219] mptsas: ioc0: attaching sata device: fw_channel 0,
> fw_id 1, phy 1, sas_addr 0x1221000001000000
> [Mar01 135219] scsi target4:0:2: mptsas: ioc0: delete device:
> fw_channel 0, fw_id 1, phy 1, sas_addr 0x1221000001000000
> [Mar01 135220] mptbase: ioc0: RAID STATUS CHANGE for VolumeID 0
> [Mar01 135220] mptbase: ioc0:   volume is now degraded, enabled,
> resync in progress
> [Mar01 172257] mptbase: ioc0: RAID STATUS CHANGE for PhysDisk 0 id=1
> [Mar01 172257] mptbase: ioc0:   PhysDisk is now online
> [Mar01 172257] mptbase: ioc0: RAID STATUS CHANGE for VolumeID 0
> [Mar01 172257] mptbase: ioc0:   volume is now optimal, enabled, resync
> in progress
> [Mar01 172257] mptbase: ioc0: RAID STATUS CHANGE for VolumeID 0
> [Mar01 172257] mptbase: ioc0:   volume is now optimal, enabled
> 
> 
> apar cred ca de anul trecut erori de genul, dar daca la inceput
> apareau odata pe luna, saptamana trecuta au cam aparut zilnic, si
> ultima oara, sambata vad ca a ramas la "PhysDisk is now missing, out
> of sync", nu si-a mai revenit.
> 
> Intrebari acum:
>  - cum pot sa identific care e hdd-ul care e crapat?
Fiind brand, placa raid suporta sa ii dai un "blink" la hardul defect; acum 
problema e cu ce ii dai tu comanda din SO, cu un pic de efort ar trebui sa se 
poata.

>  - daca il inlocuiesc, trebuie cumparat hdd identic cu cel din server?
>  - cum fac sa copiez datele pe un hdd nou fara sa opresc serverul? Din
> ce am inteles, ar trebui sa fie de ajuns sa infig un hdd nou si se
> prinde singur ca trebuie sa faca resync..
Prosupun ca e hot pluggable, deci cel mult trebuie sa ii spui ca ai bagat un 
replacement .
Dar problema e sa ai softul de management al raid-ului instalat. 
> 
> Ar trebui sa mentionez ca nu am nici un fel de experienta cu RAID, fie
> software, fie hw.