Question #661412 on rohc changed: https://answers.launchpad.net/rohc/+question/661412
Selvaganesan Murugesan posted a new comment: Hi Didier, Please find my answers inline below, * You seem to have configured the ROHC compressor with MAX_CID = 3 since the compressor uses CID=0,1,2,3 for packets #1-4 and then re-uses CID=0 for packet #5. Is that correct? <SELVA> Yes, that is correct. Did you specified some timing information for every packet to the ROHC compressor? <SELVA> No, I am giving 0 as the timing for all the packets. I understand that the time must be provided for each packet during the compression request, I will not be able to use the arrival time from the packet but will use the local time source then let you know the results, I hope this is ok. Are the TCP and IP-only profiles disabled? <SELVA> Yes, The only profile enabled is UDP/IP (0x0002). I hope this is ok . Thanks, Selvaganesan M. -- You received this question notification because your team ROHC Team is an answer contact for rohc. _______________________________________________ Mailing list: https://launchpad.net/~rohc Post to : rohc@lists.launchpad.net Unsubscribe : https://launchpad.net/~rohc More help : https://help.launchpad.net/ListHelp