Hi Michael,

I am not aware of such an extension, but changes might actually not
be all that difficult ...

I guess turning the step parameter from seconds into milli seconds
would be all that is required ... there would still be enough
head-room above

unfortunately such an extension would require a change in rrdtool
data format which makes it difficult to fold this back into
mainline ... but for your research the patch should be fairly
simple ...

cheers
tobi


Today [email protected] wrote:

> Hello,
>
> I am researching rrd-[developers|users] archives whether someone have
> done the extension of the RRD tool for milliseconds/sub-second stepping
> (e.g., --step 500ms) in the past?
>
> To date I found some mail threads with references to the subject but
> without an explicit success mark.
>
> Using this sub-second extension, I want to research mechanical gearboxes
> installed on remote sites in the field collecting the analogue data from
> gearbox' sensors in an RRA over 1 year via site local network. A gearbox
> aggregate has something like 150 data sources. (~50) of them need to be
> recorded with 100ms step. The system, I have in mind should work
> off-line/autonomously.
>
> With best regards,
>
> Michael
>
> _______________________________________________
> rrd-developers mailing list
> [email protected]
> https://lists.oetiker.ch/cgi-bin/listinfo/rrd-developers
>
>

-- 
Tobi Oetiker, OETIKER+PARTNER AG, Aarweg 15 CH-4600 Olten, Switzerland
http://it.oetiker.ch [email protected] ++41 62 775 9902 / sb: -9900

_______________________________________________
rrd-developers mailing list
[email protected]
https://lists.oetiker.ch/cgi-bin/listinfo/rrd-developers