[EMAIL PROTECTED] wrote: > 1026246000: 1.1249871111e+02 > 1026246300: 0.0000000000e+00 > 1026246600: 0.0000000000e+00 > > and from that moment only 0-es > > an info for that rrd file look like this: > > last_update = 1026463526 > ds[data].type = "COUNTER" > ds[data].minimal_heartbeat = 900 > ds[data].min = 0.0000000000e+00 > ds[data].max = NaN > ds[data].last_ds = "2147483647"
This is MAXINT. Probably an error in your program or in the snmp implementation of the device. To be fair: it *is* possible that the counter returned is maxint, so better check another time. If this number does stay MAXINT, it is only logical that RRDtool computes zero rate. cheers, -- __________________________________________________________________ / [EMAIL PROTECTED] [EMAIL PROTECTED] \ | work private | | My employer is capable of speaking therefore I speak only for myself | +----------------------------------------------------------------------+ | Technical questions sent directly to me will be nuked. Use the list. | +----------------------------------------------------------------------+ | http://faq.mrtg.org/ | | http://rrdtool.eu.org --> tutorial | +----------------------------------------------------------------------+ -- Unsubscribe mailto:[EMAIL PROTECTED] Help mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/rrd-users WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi