On Wed, Oct 16, 2002 at 11:38:30PM -0400, Josh Wyatt wrote: > Reading in the Fine Tutorial (in the "Data Resampling" section", and > confirming for myself, I see that RRDTool does interpolation when the > timestamp on update doesn't exactly match (database start time) + > (step)*x .
Indeed. Therefore, if you update only at the right time, no resampling will take place. If "the right time" needs to be "any time", the maximum step size for you is 1. If you have a step size of 1 (seconds per PDP) and do *not* use the AVERAGE CF, you won't end up with "1.2 people in the room". There's no need to have an RRA with 1 PDP per CDP. For instance: RRA 1 300 PDPs per CDP 600 rows CF=MIN RRA 2 300 PDPs per CDP 600 rows CF=MAX RRA 3 1800 PDPs per CDP 600 rows CF=MIN RRA 4 1800 PDPs per CDP 600 rows CF=MAX RRA 5 7200 PDPs per CDP 600 rows CF=MIN RRA 6 7200 PDPs per CDP 600 rows CF=MAX RRA 7 86400 PDPs per CDP 732 rows CF=MIN RRA 8 86400 PDPs per CDP 732 rows CF=MAX HTH Alex -- Unsubscribe mailto:[EMAIL PROTECTED] Help mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/rrd-users WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi