Hi Tobi, try to download the MIB file from cisco website -> CISCO-PROCESS-MIB
then try to map this oid from this MIBs 1.3.6.1.4.1.9.9.109.1.1.1.1 -> cpmCPU then from this table you will get your specific OID of your device 1.3.6.1.4.1.9.9.109.1.1.1.1 -> cpmCPUTotalEntry 1.3.6.1.4.1.9.9.109.1.1.1.1.1 -> cpmCPUTotalIndex 1.3.6.1.4.1.9.9.109.1.1.1.1.2 -> cpmCPUTotalPhysicalIndex 1.3.6.1.4.1.9.9.109.1.1.1.1.3 -> cpmCPUTotal5sec 1.3.6.1.4.1.9.9.109.1.1.1.1.4 -> cpmCPUTotal1min 1.3.6.1.4.1.9.9.109.1.1.1.1.5 -> cpmCPUTotal5min 1.3.6.1.4.1.9.9.109.1.1.1.1.6 -> cpmCPUTotal5secRev 1.3.6.1.4.1.9.9.109.1.1.1.1.7 -> cpmCPUTotal1minRev 1.3.6.1.4.1.9.9.109.1.1.1.1.8 -> cpmCPUTotal5minRev you can used snmpwalk for this OID's to map regards, Ed At 05:06 PM 1/30/2004, [EMAIL PROTECTED] wrote: >Hi People, >im looking for the oid´s for my Cisco WS-C5505 Switch. >I want to monitor the CPU Usage. > >hope someone could help me. > >Thanks >Tobias Liefke > >InFoScore >Software Service GmbH >Rheinstrasse 99 >D-76532 Baden-Baden >tel.: +49 (0) 72 21/ 50 40 40 90 >email: [EMAIL PROTECTED] >web: www.infoscore.de >-- >Unsubscribe mailto:[EMAIL PROTECTED] >Help mailto:[EMAIL PROTECTED] >Archive http://www.ee.ethz.ch/~slist/rrd-users >WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi -- Unsubscribe mailto:[EMAIL PROTECTED] Help mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/rrd-users WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi