I fixed it. But your idea can work too.:-) I changed the value COUNTER to DERIVE and i set the MIN to 0. It works good.
Thank for your answer. D. -----Original Message----- From: Simone Felici - Alpikom Spa [mailto:[EMAIL PROTECTED] Sent: Thursday, April 22, 2004 8:47 AM To: KAMARAD, David; [email protected] Subject: R: [rrd-users] Problem with counters Hello! I check first of all the router uptime. If it's higher than 5 minutes, then I update my graph with the values, otherwise I update it with "U" (unknown) value. Hope it helps! ...for me yep ;) And remember it's better to set a min/max value limit to prevent peaks :) Bye Simon > -----Messaggio originale----- > Da: [EMAIL PROTECTED] > [mailto:[EMAIL PROTECTED] Per conto di KAMARAD, David > Inviato: mercoledì 21 aprile 2004 10.17 > A: [email protected] > Oggetto: [rrd-users] Problem with counters > > > Hi, > > I have a problem with my counters on device. I use RRD values as > COUNTER for OCTETS. When the router is reloded, the counters beginning > from zero and my graph of rates is unusable for one or two cycles. > > Do you have anybody some idea? Can I fix it by RRD tool? > > Thank you very much for help.. > > David > > > > -- > Unsubscribe > mailto:[EMAIL PROTECTED]> subject=unsubscribe > > Help > mailto:[EMAIL PROTECTED] > Archive http://www.ee.ethz.ch/~slist/rrd-users > WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi > > -- Unsubscribe mailto:[EMAIL PROTECTED] Help mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/rrd-users WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi