Noone can helo me with this little problem and resolve my confused ideas? In simple words I would create my rrd COUNTER32 traffic files setting a correct MAX value for example with MAX limit not over MAX line speed +50%.
Example a 2Mbit Line should have a rrd file with max value allowed not over 3Mbit, to prevent strange peaks. Also what should I set creating the file? (DS:ds-name:DST:heartbeat:min:***MAX***) Thank's to all! Simon > Hello to all! > > First of all I've read the tutorials, but I'm little bit > confused about COUNTER32 bits and bytes also I'll ask you a > simply and so stupid question > If I've created the following RRD File: > DS[eth0_in] typ: COUNTER hbt: 600 min: 0.0000 max: > 3000000.0000 > DS[eth0_out] typ: COUNTER hbt: 600 min: 0.0000 max: > 3000000.0000 > In my graph, what will be the maximum Kb/s that the RRA could > save without fall into Unknown value caused from the max setting? > If I'm not wrong the data are collected/stored in BYTES, > right? It means the highest value stored cannot be higher > than 3000000 BYTES? (=24Mbit/s shown into a graph?). > Thank's > Simon -- Unsubscribe mailto:[EMAIL PROTECTED] Help mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/rrd-users WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi