[ Comments below, in line ]
On Monday 29 June 2009 at 11:41 am, R Dicaire penned
about "[rrd-users] GAUGE negative values"
> If I understand the documentation correctly, type GAUGE cannot have
> negative values input into the rrd database?
>
Howdy,
Adding to what Tobi said, yes GAUGE has no issues with negative
values. Below is an excerpt of my RRD creation. I think the metrics
are obvious. :)
rrdtool create $GENERAL_FILE --step $COLLECTION_INTERVAL_5M \
DS:temperature:GAUGE:$UNKNOWN_5M:-90:80 \
DS:humidity:GAUGE:$UNKNOWN_5M:0:100 \
DS:barometer:GAUGE:$UNKNOWN_5M:700:1050 \
DS:daily_rain:GAUGE:$UNKNOWN_5M:0:1000 \
DS:wind_chill:GAUGE:$UNKNOWN_5M:-100:1.67 \
DS:humidex:GAUGE:$UNKNOWN_5M:9:80 \
DS:dew_point:GAUGE:$UNKNOWN_5M:-100:80 \
Cheers,
--
Pablo Sanchez - Blueoak Database Engineering, Inc