Rick Jones wrote: > > illegal attempt to update using time 1303164367 when last update time > > is 1303164367 (minimum one second step)
AIUI, if you use "N" (now) for the update time, then internally RRD uses sub-second timing and you can update more frequently. It does mean that your update "happens" when you submit the call rather than when you take the timestamp, but for your setup I doubt that's a huge issue. -- Simon Hobson Visit http://www.magpiesnestpublishing.co.uk/ for books by acclaimed author Gladys Hobson. Novels - poetry - short stories - ideal as Christmas stocking fillers. Some available as e-books. _______________________________________________ rrd-users mailing list rrd-users@lists.oetiker.ch https://lists.oetiker.ch/cgi-bin/listinfo/rrd-users