On 29/01/2014 6:18 am, Ric Claus wrote:
Hi Chris,
This looks great! Thanks for doing it. I was just starting to think about
solving this problem, so I am grateful that you beat me to it. :-)
Along similar lines, in a system where one has multiple different model
ZYNQs running at different clock speeds, but otherwise identical from the
software point of view, is it possible to make one RTEMS build satisfy them
all? In other words, can you think of a solution wherein the clock speed is
determined or set at run time rather than build time?
I have pushed patches recently where functions are weak and called when
provided by a users during initialisation to get specific set ups or
values. The ones I have provided are the MMU set up and a clock
frequency for the timer. The use of these functions allows you to manage
the configuration or configurations.
Chris
_______________________________________________
rtems-devel mailing list
rtems-devel@rtems.org
http://www.rtems.org/mailman/listinfo/rtems-devel