On 2014-02-17 22:41, Chris Johns wrote:
On 18/02/2014 2:51 am, Sebastian Huber wrote:
Merge systems states SYSTEM_STATE_SHUTDOWN and SYSTEM_STATE_FAILED into
new system state SYSTEM_STATE_FATAL. This reflects that all system
termination paths end up in _Internal_error_Occurred().
Does this mean non-error termination happens here ? If so is the naming
suitable ?
Yes, all (non-error and error) termination paths end up here. The name
reflects the user extension name that is invoked here. Since this name is part
of the public API we should not change it.
--
Sebastian Huber, embedded brains GmbH
Address : Dornierstr. 4, D-82178 Puchheim, Germany
Phone : +49 89 189 47 41-16
Fax : +49 89 189 47 41-09
E-Mail : sebastian.hu...@embedded-brains.de
PGP : Public key available on request.