Thanks Paolo

Is this independent of the length of the interval?

Daniel


>From: Paolo Mantegazza <[EMAIL PROTECTED]>
>To: daniel sheltraw <[EMAIL PROTECTED]>
>Subject: Re: [rtl] precision/accuracy question
>Date: Thu, 25 May 2000 13:07:39 +0200
>
>daniel sheltraw wrote:
> >
> > Hello RTAIers
> >
> > What is the accuracy/precision of the time returned by rt_get_time()?
> > Is it approximately the same for short intervals (< 1 second) and
> > for long intervals (> 1 second)? Is the same counter/timer used for
> > long and short intervals? I am using a 400 Mhz Pentium II.
> >
> > Daniel
>
>If the timing is periodic the accuracy is in periods.
>
>If the timing is oneshot the acuuracy is 2.5 nanos.
>
>Ciao, Paolo.