Hi everybody,

I just switch over to the latest version of rtnet. Before I worked fairly long
with the "historic" 0.6.0 with some patches.

I have found one issue that worked with the old version but does not work with
the latest version:
I am using two eepro100 adapters as two real time network devices.
I want to access two non-rtnet embedded devices that have both the same fix IP 
address. 

In previous versions of rtnet the routing was done using the source and the
destination address, now only the destination address is in use for routing.
That means, that it is not possible in my  setup to distinguish between
the two embedded devices.
In the previous version, I set a different IP address to each of the NICs and 
this
allowed me to access both embedded devices (the source address was relevant).


What can I do? I looked into the code and found out, that this issue
is not a trivial one as a extension of the routing (including API interface)
has to be done.

Thanks for any idea/help on this issue.

Regards

Mathias





-- 
Mathias Koehrer
[EMAIL PROTECTED]


Viel oder wenig? Schnell oder langsam? Unbegrenzt surfen + telefonieren
ohne Zeit- und Volumenbegrenzung? DAS TOP ANGEBOT JETZT bei Arcor: günstig
und schnell mit DSL - das All-Inclusive-Paket für clevere Doppel-Sparer,
nur  44,85 €  inkl. DSL- und ISDN-Grundgebühr!
http://www.arcor.de/rd/emf-dsl-2


-------------------------------------------------------
All the advantages of Linux Managed Hosting--Without the Cost and Risk!
Fully trained technicians. The highest number of Red Hat certifications in
the hosting industry. Fanatical Support. Click to learn more
http://sel.as-us.falkag.net/sel?cmd=lnk&kid7521&bid$8729&dat1642
_______________________________________________
RTnet-users mailing list
RTnet-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/rtnet-users

Reply via email to