Karl Reichert schrieb:
> Hi,
> 
> I have some questions concerning tdmacfg tool:
> 
> I want to configure my station as tdma master with 200 ms between timeslots 
> and master using first tdma slot (right after sync, because there is no 
> backup master). Cycle length may be 5000 ms, only RT data will be sent. So I 
> run
> tdmacfg rteth0 master 5000 -c 1 -i 1
> tdmacfg rteth0 slot 0 200 -l rtnet.log
> 
> How do I tell the master when it's timeslot ends. Is this only possible via 
> -s <size> parameter?

Yes. A timeslot of current TDMA can take up to one frame, thus the frame 
length implicitly defines the slot length.

Jan

-------------------------------------------------------------------------