On 2013-08-27 12:22, Jan Kiszka wrote:
> On 2013-08-27 12:20, Sebastian Hölzer wrote:
>> Hi,
>>
>> i got my setup running still using RTAI. I can use rtping and run the rtai
>> example.

What was the trick?

>>
>> However after starting the rtnet script the rt_e1000e driver says
>> "rt_e1000e: Reset adapter" several times.
>>
>> After a few resets the communication is established.
>> Do you have any idea why this is happening?

You could compare these resets with those triggered by the Linux driver
during startup. I don't know by heart how often this triggers, but I
know that the startup phase takes a while here as well.

>>
>> Another thing i noticed is that the ping time varies within the range of
>> cycle time up to two times the cycle time.
>> Is this the normal behavier?

Yes. Just think about the asynchronous timing, when the external event
arrives and when it can be delivered over the cyclic channel.

>>
> 
> Please send via the mailing list.

Oops, now I added the CC already.

Jan

-- 