The DLL in v4 should be more recent then one in 2.x and thus incorporate all changes...
Dirk. Woodstone is moving it's offices to a new location. Response to email will be delayed due to this. -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] Behalf Of Peter Martin Sent: Thursday, June 12, 2003 10:30 AM To: [EMAIL PROTECTED] Subject: Re: [SA-list] Alpha Page Problem sendin Dirk, I've done as requested and still no joy, the wierd is that its actually picking the modem up, dialing the number and then hanging up, with the log entry that says it's failed, as per the log below. I remember having a problem with this in SA2x which was down to a paging dll that didn't like my setup, you got me a new working version, I wonder it that new DLL is interferring with the V4 one? Regards Peter Martin IT Operations Manager Initial Electronic Security t. 01282 473561 f. 01254 267549 e. [EMAIL PROTECTED] ----- Original Message ----- From: "Dirk Bulinckx" <[EMAIL PROTECTED]> To: <[EMAIL PROTECTED]> Sent: Wednesday, June 11, 2003 3:09 PM Subject: RE: [SA-list] Alpha Page Problem sendin > The log shows that the OS gives no available TAPI devices -> no modem. > Try to reinstall the modem under the OS > > Dirk. > > Woodstone is moving it's offices to a new location. Response to email will > be delayed due to this. > > -----Original Message----- > From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] > Behalf Of Peter Martin > Sent: Wednesday, June 11, 2003 3:10 PM > To: [EMAIL PROTECTED] > Subject: [SA-list] Alpha Page Problem sending > > > Hi all, > > My SA has stopped sending me text's to my phone in the last day, I have > confirmed that the SMSC number has not changed, and I can think of any > changes made to the machine, I've turned logging on to max and seen the > below, why does SA not think I have any telephony devices, I have a modem > configured and works if I test with DUN? > > Any ideas? > > 11 June 2003 13:40:02 Netware library's not available > 11 June 2003 13:40:02 NT Service check not possible on Win9x > 11 June 2003 13:40:02 DUN installed and available for SA > 11 June 2003 13:40:03 TAP ERROR: There are no telephony devices installed. > ( 26001) > 11 June 2003 13:40:03 TAP ERROR: There are no telephony devices installed. > ( 26001) > 11 June 2003 13:40:03 UCP ERROR: There are no telephony devices installed. > ( 26001) > 11 June 2003 13:40:03 UCP ERROR: There are no telephony devices installed. > ( 26001) > 11 June 2003 13:40:03 Check cycle starts ( 0- 1) > 11 June 2003 13:40:04 ntsqladmin-master: (normal) > > 11 June 2003 14:00:53 PAGING : Comm 0 > 11 June 2003 14:00:53 PAGING : RECIP 07967705771 > 11 June 2003 14:00:53 PAGING : REQ F > 11 June 2003 14:00:53 PAGING : TEXT Radius Server Request for Auth is DOWN > 11 June 2003 14:00:53 PAGING : SMSC 907973100601 > 11 June 2003 14:00:53 PAGING : PROTO 1 > 11 June 2003 14:00:53 TAP DEBUG: Starting sending thread. ( 26400) > 11 June 2003 14:00:53 TAP DEBUG: Sending thread starting up. ( 26400) > 11 June 2003 14:00:53 TAP DEBUG: Logon procedure started. ( 26101) > 11 June 2003 14:01:38 Checking Radius Server Request for Auth > 11 June 2003 14:01:38 Radius check (192.191.191.223) failed : REJECT > 11 June 2003 14:01:51 TAP ERROR: Disconnected: No answer. ( 26018) > 11 June 2003 14:01:51 TAP remove #PHONE=07967705771#MESSAGE=Radius Server > Request for Auth is DOWN#REDI=0#(#PHONE=07967705771#MESSAGE=Radius Server > Request for Auth is DOWN#REDI=0#) > 11 June 2003 14:01:51 TAP DEBUG: Logon: failed. ( 26104) > 11 June 2003 14:01:51 TAP STATUS: Message sending failed. (ID: 2) ( 26315) > 11 June 2003 14:01:51 TAP STATUS: The transmission is completed. (ID: -1) > ( 26313) > 11 June 2003 14:02:01 TAP wait (S- 26313)10 > 11 June 2003 14:02:01 PAGING : Comm 0 > 11 June 2003 14:02:01 PAGING : RECIP 07967705771 > 11 June 2003 14:02:01 PAGING : REQ F > 11 June 2003 14:02:01 PAGING : TEXT Radius Server Request for Auth is DOWN > 11 June 2003 14:02:01 PAGING : SMSC 907973100601 > 11 June 2003 14:02:01 PAGING : PROTO 1 > 11 June 2003 14:02:01 TAP DEBUG: Starting sending thread. ( 26400) > 11 June 2003 14:02:01 TAP DEBUG: Sending thread starting up. ( 26400) > 11 June 2003 14:02:01 TAP DEBUG: Logon procedure started. ( 26101) > 11 June 2003 14:02:01 TAP wait (E- 26018)10 > 11 June 2003 14:02:01 PAGING : Comm 0 > 11 June 2003 14:02:01 PAGING : RECIP 07967705771 > 11 June 2003 14:02:01 PAGING : REQ F > 11 June 2003 14:02:01 PAGING : TEXT Radius Server Request for Auth is DOWN > 11 June 2003 14:02:01 PAGING : SMSC 907973100601 > 11 June 2003 14:02:01 PAGING : PROTO 1 > 11 June 2003 14:02:01 TAP ERROR: Sending is already active. ( 26312) > 11 June 2003 14:02:11 TAP wait (E- 26312)10 > 11 June 2003 14:02:40 TAP DEBUG: Logon: failed. ( 26104) > 11 June 2003 14:02:40 TAP STATUS: Message sending failed. (ID: 3) ( 26315) > 11 June 2003 14:02:40 TAP STATUS: Message sending failed. (ID: 4) ( 26315) > 11 June 2003 14:02:40 TAP STATUS: The transmission is completed. (ID: -1) > ( 26313) > 11 June 2003 14:02:40 TAP remove #PHONE=07967705771#MESSAGE=Radius Server > Request for Auth is DOWN#REDI=1#(#PHONE=07967705771#MESSAGE=Radius Server > Request for Auth is DOWN#REDI=1#) > 11 June 2003 14:02:40 Check cycle starts ( 2- 3) > > Regards > > Peter Martin > IT Operations Manager > Initial Electronic Security > t. 01282 473561 > f. 01254 267549 > e. [EMAIL PROTECTED] > > To unsubscribe from a list, send a mail message to [EMAIL PROTECTED] > With the following in the body of the message: > unsubscribe SAlive > > > To unsubscribe from a list, send a mail message to [EMAIL PROTECTED] > With the following in the body of the message: > unsubscribe SAlive To unsubscribe from a list, send a mail message to [EMAIL PROTECTED] With the following in the body of the message: unsubscribe SAlive To unsubscribe from a list, send a mail message to [EMAIL PROTECTED] With the following in the body of the message: unsubscribe SAlive