2nd thing can be done in another way:
Some months back Dirk added an option to execute a SQL statement before the insert.
"...Create
HKEY_LOCAL_MACHINE\SOFTWARE\DBU Consulting\Servers
Alive\Interchange\db_sqlcmd_before (string) and give the correct SQL statement to
execute
It will be executed before the interchange logging starts adding records (the command
won't be executed if the interchange logging is disabled ofcourse)"
Put "delete * from interchange_table" in this key and you've got your current status.
Johan
-----Original Message-----
From: Dirk Bulinckx [mailto:[EMAIL PROTECTED]
Sent: maandag 27 oktober 2003 15:34
To: [EMAIL PROTECTED]
Subject: RE: [SA-list] Dreaming of features for version 5.....
The 2nd thing can be done :-)
Use the interchange file export and create an app that insert this into
a db. And instead of doing an append this just does an update (or add).
This app can then be execute by SA after the generation of the
interchange file.
dirk.
-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On
Behalf Of Michael Shook
Sent: Mon Oct 27 3:07 PM
To: [EMAIL PROTECTED]
Subject: [SA-list] Dreaming of features for version 5.....
The discussions around the stats table (the regedit of which is being
tested this morning - Thanks Dirk!!!) got me to thinking about tables
that SA could create that would save me time and effort in the future
(especially when I have to explain SA to the Network team!!!)
The first is as had been mentioned where SA keeps track of the timing
for all of the states a check has been in for a given period of time and
then sends that to a database on a regular schedule.
The second is exactly the same as the current interchange database table
EXCEPT that it only keeps the results of the last check cycle (like the
interchange file). This would also assist the gentleman who wanted a
list of the current hosts being checked. I love the history, but it's a
bit of a challange to get the latest test results.
The third is a database with only one record, the fields being all of
what is available via HTML tags for the SA software itself and the top
level group (sa_version, sa_cycles, sa_group_up_entries, etc....).
Here's to dreaming!!
Michael Shook
Business Continuity Analyst
Saddle Creek Corporation
723 Joe Tamplin Industrial Blvd
Macon GA 31217
478 742 8740 ext. 105 (work)
478 256 9318 (mobile)
478 742 7917 (fax)
[EMAIL PROTECTED]
http://www.saddlecrk.com
To unsubscribe from a list, send a mail message to [EMAIL PROTECTED]
With the following in the body of the message:
unsubscribe SAlive
To unsubscribe from a list, send a mail message to [EMAIL PROTECTED]
With the following in the body of the message:
unsubscribe SAlive
To unsubscribe from a list, send a mail message to [EMAIL PROTECTED]
With the following in the body of the message:
unsubscribe SAlive