RMS Sequential Variable files produced on VMS cannot be read as expected by
Windows programs. They expect <CR><LF> pairs to be embedded in the data, and
they aren't there. The "Record Attributes" are meaningless here (no
extraneous data is retieved from/written to the file).

In order to be readable by Windows programs, files on VMS must have RMS
attributes showing a record format of Stream or Stream_LF.

David J Dachtera
DJE Systems 

-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of
[EMAIL PROTECTED]
Sent: Thursday, January 03, 2008 2:38 AM
To: [email protected]
Subject: Record format

We have recently installed Samba on VMS (Itanium).

We have problems in reading text-files produced on VMS. The CR/LF does not 
work. The data stream appears in a long line.

The file attributes on VMS are:

Record format: Variable length, maximum 0 bytes, longest 75 bytes 
Record attributes: Carriage return carriage control

Do I have to change these attributes or is there anything to do in the 
SMB.CONF file?

RG Rolf
PLEASE READ THIS IMPORTANT ETIQUETTE MESSAGE BEFORE POSTING:

http://www.catb.org/~esr/faqs/smart-questions.html

PLEASE READ THIS IMPORTANT ETIQUETTE MESSAGE BEFORE POSTING:

http://www.catb.org/~esr/faqs/smart-questions.html