Did you make the required registry changes
http://wiki.samba.org/index.php/Windows7
HKLM\System\CCS\Services\LanmanWorkstation\Parameters
DWORD DomainCompatibilityMode = 1
DWORD DNSNameResolutionRequired = 0
Do you have problems with XP machines?
On 12/22/2011 02:28 PM, John G. Heim wrote:
I have a PDC running debian wheezy with samba 3.5.11 . If I run 'net
rpc testjoin' on my PDC, it does this:
# net rpc testjoin
get_schannel_session_key: could not fetch trust account password for
domain 'UW-MATH'
net_rpc_join_ok: failed to get schannel session key from server HUBBLE
for domain UW-MATH. Error was NT_STATUS_CANT_ACCESS_DOMAIN_INFO
Join to domain 'UW-MATH' is not valid: NT_STATUS_CANT_ACCESS_DOMAIN_INFO
The backend is openldap and I can find the name of my PDC in the ldap
database. It appears to have a valid machine trust account based on
the ldap record.
The main problem I'm having is that after I joined a Win7 machine to
the domain, I can't log in as a domain user. It says "The trust
relationship between this workstation and the domain failed."
--
To unsubscribe from this list go to the following URL and read the
instructions: https://lists.samba.org/mailman/options/samba