Hi Olaf, > Sorry for not chiming in earlier.
No worries, I'm happy you gave me additional pointers. > > I have been involved with development of the third-party epkowa and > utsushi backends for many years. A lot of the protocol is documented in > the code for the utsushi backend via doxygen source comments. See > > https://gitlab.com/utsushi/utsushi/-/tree/master/drivers/esci Ok, more documentation sounds nice. I still have questions about the gamma tables. I will check. One thing I could not find out yet: are there any advantages for me when I use epkowa? I think epson2 does a nice job and it can easily be extended? > # I guess I could add a job to publish the documentation in a more > # accessible format via GitLab Pages. Please submit an issue if you > # would like that. Well, if it is just for me, I like to read code, so not really needed. But for others, it might be helpful. Then again, you probably are not short of tasks. > There are two documented values: 0xff for autofocus and 0x40 for setting > it to the glass plate. Other values appear to be allowed. And they make sense. Using the extreme values I get blurred images. > > The only question left for me now: Should focus/autofocus settings > > really have CAP_ADVANCED? > > That's debatable indeed but I'd say CAP_ADVANCED is appropriate for most > users. Ok, then, I'll keep it! Thanks, Wolfram
signature.asc