On Sun, 2002-09-22 at 22:48, Henning Meier-Geinitz wrote: > Hi, > > I'm interested in reports from testers. Especially if I broke the > GT-6816 scanners (BearPaw 1200TA, 2400TA) while changing the > gain/exposure control. And I want to know, which resolutions work for > which scanner. I can only test the BearPaw 1200 CU currently.
Here are the results for a mustek 1200 UB Plus, with full scan, safe preview and automatic gain turned off, 8bits depth, enhancement and geometry with default values. W&B: 50, 75, 150, 300, 600 dpi work well now For 1200 dpi, the scan process seems to work, but when I try to load the pnm file gimp says "premature end of file" (or something like that). However the pnm file is really big (144 MB) and it may be a problem with gimp. Color: 50, 75, 150, 300, 600 dpi work well too with very good colors now. Same problem as W&B for 1200 dpi (ohh my god it takes one hour to scan a full A4 page at 1200dpi with this scanner). However for color and w&b if I scan just a little part of the image the resulting file is loaded by gimp. The scan head never bumped out of the scan area while I was testing. -- Irvin Probst