Hi, On Mon, Mar 25, 2002 at 10:06:12AM -0800, Dave Close wrote: > Again, I never saw this on the list, only in a personal copy to me. > Unfortunately, I tend to ignore off-list replies to list posts.
The post was on the list, at least I read it here. > I had mentioned SANE_DESC_SCAN_SPEED, SANE_DESC_CAL_LAMP_DEN, > SANE_DESC_SCAN_LAMP_DEN, and SANE_DESC_SELECT_LAMP_DENSITY. All of > these are listed in saneopts.h. If they are hardware-dependent, they > should not appear there, but should appear only in the header file > associated with the specific backend. I don't know why they have been added, it's long time ago. Generally, saneopts.h is just a list of common descriptions to help authors and avoid similar names for the same option. They are not a standard for how an option is implemented. The backend auther even doesn't need to use these names. > Note that nearly all options are implemented differently for different > scanners. The fact that the implementation varies is no reason for an > option not to be standard, or "well known". My assertion is that any > option which appears in saneopts.h should be considered well known and > its usage should be well defined. Not all options in saneopts.h are well-known, only those in the standard. Only well-known options must use the same types etc. > I also don't see why scanning speed should be less standardized than > brightness or contrast (for example), or specifically for the scanning > mode (gray, mono, lineart, etc). All this is hardware-dependant and therefore curently no well-known option. Not all scanners have brightness or contrast. Some habe halftone mode, others haven't. Some even don't have a color mode. For some Mustek scanners there are 5 speed options (slowest to fastest). For other scanners there may be 20 or only 2. I don't think it makes much sense to standardize this. There will be more well-known options in the next version if the SANE standard but I don't think "speed" should be one of them. > Can anyone answer my specific question about the LAMP options: should I > understand that "density" is, in some sense, equivalent to "intensity"? I have no idea. > >In general the frontend does not need to know about the options. > > That may be true in the general case. I prefaced my post by noting that > "our practice is to provide a standard user interface for all of our > scanners." In a production environment, with technicians working on > several scanners and work generated by departments which never see the > scanners, a standard interface helps a great deal. We may be unique but > I suspect there are other production situations among SANE users. SANE > is not defined, so far as I know, as a hobbiest protocol only. SANE is a standard that describes communication between a backend that knows the hardware and a frontend that doesn't (and shouldn't). That's why the hardware parameters are encapsulated in SANE options. SANE doesn't mean: every scanner looks the same. It doesn't. To solve your problem: you may want to write a meta backend that translates the options of the various backends you use to something you like. Maybe you can use dll.c as a base. Or just change the source of the backends you use if you like. Bye, Henning