This is an informational message and does not require a reply. It is being sent so that others that have this problem will not spend forever troubleshooting it but can find it with a search of this mail list.
I use a BusLogic BT 545C ISA SCSI card to hook up a UMAX-1200C scanner. With SUSE 7.1 (kernel 2.4.2 SMP) I have two problems with this setup when using sane/xsane. 1) At various times the scan will abort almost after it has started leaving only a few number of lines. [umax] umax_reader_process: buffer of 121896 bytes read; 124166313 bytes to go [umax] umax_queue_read_image_data_req for buffer[0] [sanei_scsi] scsi_req_enter: entered 0x409ea008 [sanei_scsi] sanei_scsi.issue: 0x409ea008 [sanei_scsi] scsi_req_enter: queue_used: 2, queue_max: 2 [umax] umax_queue_read_image_data_req: id for buffer[0] is 0x409ea008 [umax] umax_reader_process: read image data queued for buffer[0] [umax] umax_wait_queued_image_data for buffer[1] (id=0x40a2c008) [sanei_scsi] sanei_scsi_req_wait: waiting for 0x40a2c008 [sanei_scsi] sanei_scsi.issue: 0x40a2c008 [umax] sane_read: read 4096 bytes [umax] sane_read: read 4096 bytes [umax] sane_read: read -1 bytes [umax] sane_read: EAGAIN [sanei_scsi] sanei_scsi.issue: 0x409ea008 [sanei_scsi] sanei_scsi_req_wait: read 64 bytes [sanei_scsi] sanei_scsi_req_wait: SCSI command complained: Success [sanei_scsi] sense buffer: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 [sanei_scsi] target status: 00 host status: 0007 driver status: 0027 [umax] umax_wait_queued_image_data: wait returned status Error during device I/O [umax] ERROR: umax_reader_process: unable to get image data from scanner! [umax] reader_process: freeing SCSI buffer[1] 2) If scanning in 8 bit mode RGB and width * height of chip is an odd value then the scan will not finish. Several lines at the end of the scan will be missing. [umax] umax_reader_process: buffer of 121896 bytes read; 76185 bytes to go [umax] umax_queue_read_image_data_req for buffer[0] [sanei_scsi] scsi_req_enter: entered 0x409ea008 [sanei_scsi] sanei_scsi.issue: 0x409ea008 [sanei_scsi] scsi_req_enter: queue_used: 1, queue_max: 2 [umax] umax_queue_read_image_data_req: id for buffer[0] is 0x409ea008 [umax] umax_reader_process: read image data queued for buffer[0] [umax] umax_wait_queued_image_data for buffer[0] (id=0x409ea008) [sanei_scsi] sanei_scsi_req_wait: waiting for 0x409ea008 [sanei_scsi] sanei_scsi.issue: 0x409ea008 [umax] sane_read: read 4096 bytes [umax] sane_read: read 4096 bytes [umax] sane_read: read -1 bytes [umax] sane_read: EAGAIN [sanei_scsi] sanei_scsi_req_wait: read 64 bytes [sanei_scsi] sanei_scsi_req_wait: SCSI command complained: Success [sanei_scsi] sense buffer: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 [sanei_scsi] target status: 00 host status: 0007 driver status: 0027 [umax] umax_wait_queued_image_data: wait returned status Error during device I/O [umax] ERROR: umax_reader_process: unable to get image data from scanner! In order to fix number 1, I have to set "option scsi-maxqueue 1". In order to fix number 2 I have to make sure that width * height is an even value or use 10 bit mode. I have tested various configurations and have observed the following: USED NON SMP KERNEL Same problems as above USED ADAPTEC PCI 2940 Both problems 1 and 2 gone. No problems USED 2.2.20 SMP KERNEL Both problems 1 and 2 gone. No problems USED 2.4.18 SMP KERNEL Same problems as above It is clear from the above data that there is a problem with the device driver in 2.4 kernels for BusLogic SCSI cards. I have emailed the original author with the data above but since BusLogic cards are not that popular I don't know if it will ever be fixed. Bruce Forsberg