On 2003.03.14 21:25 Pigeon wrote: > I have a Mustek 1200CP scanner and the latest versions of sane: > [...] > It appears that the scanner carriage is advancing two steps when the > software thinks it has only advanced one step. Scanning anything > larger than half the length of A4 results in the carriage attempting > to overrun the end of its travel with unpleasant slipping of gears. > All scans come out "squashed" and need to be expanded 2:1 in the > vertical direction.
Does it happen at all resolutions? What you describe looks as if you are using the 1200CP settings on a 600CP. I presume that you are sure that it's a 1200CP ? You could try the 600CP setting and see what it gives. Another thing you could try is to disable fast skipping in your mustek_pp.conf, eg.: scanner Mustek_1200CP 0x378 1200 option slow_skip But be careful and limit the height of the scans to at most 1/2 of the page. The gear slipping isn't very healthy. > Also, the light flashes on and off rapidly during the scan; I am not > sure if this is related. It normally flashes about 1 time per second, but it isn't controlled by the driver. Eddy