--FL5UXtIhxfXey3p5 Content-Type: text/plain; charset=us-ascii Content-Disposition: inline Content-Transfer-Encoding: quoted-printable
On Sun, Jan 05, 2003 at 06:16:50PM +0100, Henning Meier-Geinitz wrote: [ ... ] > Are you sure you are using the epson backend from SANE 1.0.9 and not > the Epson software (KOWA)? I'm pretty sure that this is the problem: I just checked the epson_kw backend sources and it uses a list only for those scanners that can only handle specific resolution values. Most EPSON scanners handle any resolution between the lowest and highest resolution in the list that the scanner reports. The Perfection 1200 is a scanner that will therfore trigger the range constraint in the backend. Karl Heinz --=20 Karl Heinz Kremer [email protected] PGP Key at http://www.khk.net/download/khk.asc EPSON Sane Backend: http://www.khk.net --FL5UXtIhxfXey3p5 Content-Type: application/pgp-signature Content-Disposition: inline -----BEGIN PGP SIGNATURE----- Version: GnuPG v1.0.7 (GNU/Linux) iD8DBQE+GK7Wxejv3RfKrhsRAhg7AJ98/i+MjkxlHTZUtrQree0H7dNGCwCeMmqs yBlIJg5/fmdEo1hHEJmPJN8= =AhRd -----END PGP SIGNATURE----- --FL5UXtIhxfXey3p5--
