I use linux mandrake 9.0 , downloaded an compiled sane-backends 1.0.9 with the latest scanimage souce. If I use the scanner in=20 windows and then switch to linux, it works fine; but no chance if I do it directly after powering down the scanner. The debug output is: [sanei_debug] Setting debug level of snapscan to 2. [snapscan] usb_write Only 0 bytes written [snapscan] mini_inquiry: snapscan_cmd command failed: Error during device= I/O [snapscan] snapscani_check_device: mini_inquiry failed with Error during=20 device I/O. [snapscan] usb_read Only 0 bytes read and this is my proc/bus/usb/devices: T: Bus=3D01 Lev=3D00 Prnt=3D00 Port=3D00 Cnt=3D00 Dev#=3D 1 Spd=3D12 M= xCh=3D 2 B: Alloc=3D 17/900 us ( 2%), #Int=3D 1, #Iso=3D 0 D: Ver=3D 1.00 Cls=3D09(hub ) Sub=3D00 Prot=3D00 MxPS=3D 8 #Cfgs=3D 1 P: Vendor=3D0000 ProdID=3D0000 Rev=3D 0.00 S: Product=3DUSB UHCI Root Hub S: SerialNumber=3De400 C:* #Ifs=3D 1 Cfg#=3D 1 Atr=3D40 MxPwr=3D 0mA I: If#=3D 0 Alt=3D 0 #EPs=3D 1 Cls=3D09(hub ) Sub=3D00 Prot=3D00 Driver= =3Dhub E: Ad=3D81(I) Atr=3D03(Int.) MxPS=3D 8 Ivl=3D255ms T: Bus=3D01 Lev=3D01 Prnt=3D01 Port=3D01 Cnt=3D01 Dev#=3D 6 Spd=3D12 M= xCh=3D 0 D: Ver=3D 1.00 Cls=3Dff(vend.) Sub=3Dff Prot=3Dff MxPS=3D 8 #Cfgs=3D 1 P: Vendor=3D04a5 ProdID=3D20b0 Rev=3D 1.20 S: Manufacturer=3DColor S: Product=3D FlatbedScanner 22 C:* #Ifs=3D 1 Cfg#=3D 1 Atr=3D40 MxPwr=3D100mA I: If#=3D 0 Alt=3D 0 #EPs=3D 3 Cls=3Dff(vend.) Sub=3Dff Prot=3Dff Driver= =3Dusbscanner E: Ad=3D81(I) Atr=3D02(Bulk) MxPS=3D 64 Ivl=3D0ms E: Ad=3D02(O) Atr=3D02(Bulk) MxPS=3D 8 Ivl=3D0ms E: Ad=3D83(I) Atr=3D03(Int.) MxPS=3D 8 Ivl=3D16ms Also I have a soft link /dev/scanner0 < /dev/usbscanner. Thank you in advance for any reply and sorry for my bad english.