Hi, what I've done: - get cvs version of backend - compiled it - copied manually the libsane-umax.so.1.0.13 to its destination - startet xsane - executed a final scan - verified, that the quality calibration is no available as an option
what I've not done so far: - checked the scsi solution. I first have to find a combination of cables and adaptors to connect my 50 pin HD SCSI controller to the 25 pin sub-d scanner :-( rgds, Rainer > Hello, > > I just updated the umax backend (sane-umax) in the CVS. > Now it disables the quality calibration for the Astra 2200 SU via USB. > When the option is set then you can not do a final scan. > > Please can someone with an Astra 2200 SU > a) connected via USB test the new version and confirm that > a1) the scanner does a final scan > a2) there is no option quality-calibration any more > b) connected via SCSI confirm that nothing has changed. > > Oliver > > --=20 > http://www.xsane.org > http://www.mostang.com/sane > http://www.rauch-domain.de > mailto:[email protected]