Hi, Le mar 25/11/2003 à 19:01, Jaeger, Gerhard a écrit :
> The ASIC is from Plustek and has been introduced in the PT12 parallel-port > model, also some Genius Scanner... The bridge is GeneSys Logic GL640 chip. OK, got all the datasheets then (took the 640 out of pure luck). > Well, probably we should share the code I started with... > I'll try and setup some info on the plustek-backend download site > at www.gjaeger.de - I'll keep you informed on that. In the meantime, > you should check the general SANE-docs for information 'bout writing > backends... I'll be going there then. > > I've seen there is another scanner with the same structure, the HP > > Scanjet 4200c; anyone here who helped develop it? > > What do you mean - same structure? Do you think this HP scanner > also includes the P98003? I don't think so. AFAIK, the Plustek U12 > (the early series) and a Genius are using the same HW. No, I just meant that this scanner was also designed from an existing parallel port scanner model by simply :) adding a parallel-to-usb chip. So I thought, maybe the design(er) of the SANE backend for this scanner will be helpful. (On the other hand, maybe another way to go would be writing a generic kernel module for the GL640, providing a pseudo lp interface; then the existing parallel plustek backend might fit above that. But I don't know enough about the SANE design and structure to tell yet.) Thanks in advance anyway ! -- Albert ARIBAUD <[email protected]>