Hi everyone, I have a Mustek Paragon 600 II EP scanner, which is not yet supported by SANE. Recently I have been writing a program to access it from Linux, reverse engineering the Windows driver to discover the protocol. The program mostly works now - it can scan a colour image of arbitrary size at various resolutions (although the quality doesn't seem to be as good as in Windows).
I'd like to add support for this scanner to one of the SANE backends, and I wondered if anyone had advice. I've looked at the SANE code, the 600 II EP protocol seems to be almost identical to the 600 II N's, except the EP uses a standard parallel port while the N uses its own special interface. So I thought the best way to proceed might be to use the same code in mustek.c for constructing the SCSI commands and higher level stuff like that, and add some new 'sanei_' functions to access the 600 II EP at a low level, maybe putting them in sanei_ab306.c? Or maybe it would be better to put it in with the other parallel port code? Any thoughts? Thanks, James