On Wednesday 08 September 2004 16:10, Nicolas FRANCOIS (AKA El Bofo) wrot= e: > I've got a HP3200C on parport (AMD 2600+ on ASUS KT333 MB, Kernel 2.4, > sane-backend 1.0.14). After successfully installing the backend, I have > some problems with parport detection. Sometimes it partially works, > sometimes I'm told I haven't got a parport ! > > An example : > > root:/usr/src/sane-backends-1.0.14/tools# ./umax_pp -p -t 1 -n > /dev/parport0 > [sanei_debug] Setting debug level of umax_pp_low to 1. > [umax_pp_low] SANE_INB level 3 > [umax_pp_low] sanei_umax_pp_InitPort(0x378,/dev/parport0) > [umax_pp_low] Using /dev/parport0 ... > UMAX 1220P scanning program version 5.1 starting ... > ppdev character device built-in. > direct hardware access built-in. > Probing scanner .... > [umax_pp_low] UMAX Astra 1220/1600/2000 P ASIC detected (mode=3D31) > [umax_pp_low] Unexpected value for for register 0x0D, expected 0x00 or > 0x40, got 0x18 ! (../backend/umax_pp_low.c:7406) > [umax_pp_low] 32 bits EPP data transfer > [umax_pp_low] Count-down value is 0x00 (../backend/umax_pp_low.c:7621) > [umax_pp_low] sendWord failed got 0xE8 instead of 0xC0 or 0xD0 > (../backend/umax_pp_low.c:4550) > [umax_pp_low] Blindly going on ..... > [umax_pp_low] sendWord failed: acknowledge not received > (../backend/umax_pp_low.c:4570) > [umax_pp_low] sendData failed got 0xE8 instead of 0xC0 or 0xD0 > (../backend/umax_pp_low.c:5400) > [umax_pp_low] Blindly going on ..... > [umax_pp_low] sendData failed: acknowledge not received > (../backend/umax_pp_low.c:5423) > [umax_pp_low] sendWord failed got 0xE8 instead of 0xC0 or 0xD0 > (../backend/umax_pp_low.c:4550) > [umax_pp_low] Blindly going on ..... > [umax_pp_low] sendWord failed: acknowledge not received > (../backend/umax_pp_low.c:4570) > [umax_pp_low] sendData failed got 0xE8 instead of 0xC0 or 0xD0 > (../backend/umax_pp_low.c:5400) > [umax_pp_low] Blindly going on ..... > [umax_pp_low] sendData failed: acknowledge not received > (../backend/umax_pp_low.c:5423) > [umax_pp_low] sendData(data,2048) failed (../backend/umax_pp_low.c:5717= ) > [umax_pp_low] cmdSetDataBuffer(initbuf) failed ! > (../backend/umax_pp_low.c:7675) > > This is what ppdiag tells me : > > root:/usr/src/sane-backends-1.0.14/tools# ppdiag > S01: parport built as module > > S02: parport0: > S02: modes:PCSPP,TRISTATE,EPP > S02: ADDR :0x378 > S02: IRQ :no IRQ used > S02: DMA :no DMA used > > S03: no parport parameters > > S10: ppdev built as module > > S12: /dev/parport0 exists ... > S12: /dev/parport0 is readable ... > S12: /dev/parport0 is writable ... > > successfull end .... > > Funny, isn't it ? I'm completly stucked, so could you help a little, or > give me some pointer for more documentation ? > > \bye
Wrong list!!! I'll forward the request to: [email protected] Gerhard