Actually, the vertical lines were not as bad as I originally thought. I was scanning a full page of text as either a color or grey scale and the vertical lines were quite noticable. Scanning as line art no vertical lines appear.
I then scanned a small color photograph and the output looks normal. So it was probably operator error. > > From: <[email protected]> > Date: 2004/03/19 Fri PM 03:16:11 EST > To: "Karsten Festag" <[email protected]> > CC: [email protected] > Subject: Re: Re: [sane-devel] Re: microtek slimscan C6 USB (black scans!) > > That worked, I can now get an image, although its quality is not so good. > The image has vertical lines through-out. I set backend-calibration to on in > the microtek2.conf file and turned it off in Xsane. > > Anything I can do to get rid of the vertical lines? > >