On Thu, 10 Feb 2005 16:02:22 +0100 Gerhard Jaeger <[email protected]> wrote:
> On Monday 07 February 2005 20:31, john wrote: > > On Mon, 7 Feb 2005 08:31:47 +0100 > > Gerhard Jaeger <[email protected]> wrote: > > > > > On Friday 04 February 2005 22:57, john wrote: > > > > Hello, > > > > > > > > I've got an antique "Primax 4800 Driect 30 bit" which is > > > > supported by the plustek_pp module. > > > > > > > > If I load the kernel module, everything works fine. But using > > > > the[direct] user-mode driver, I get this from scanimage -L: > > > > > > > > <snip> > > > > [plustek_pp] Compare data=0x7f and status=0xf, port=0x0 > > > > [plustek_pp] p48xxReadWriteTest() > > > > [plustek_pp] Can't find your model, asic = 0x77 > > > > [plustek_pp] detectScannerConnection() returns -9031. > > > > [plustek_pp] ************* ASIC9800x ************* > > > > [plustek_pp] ResetPort() > > > > [plustek_pp] IOInitialize() > > > > [plustek_pp] * using readfunction >fnBiDirRead< > > > > [plustek_pp] ASIC = 0x00 > > > > [plustek_pp] Unknown ASIC-ID > > > > [plustek_pp] *** DETECTION DONE, result: -9020 *** > > > > <snip> > > > > No scanners were identified. > > > > > > > > I've tested on Debian unstable (2.4 kernel) and Slackware > > > > current(2.6 kernel) with the same results. Cn anyone point me to > > > > where I should start looking for the problem? > > > > > > > Hi, > > > > > > this could be because of different timing behaviour, when > > > accessing a device via kernel directly or via user-mode > > > application. As you didn't send the complete debug stuff, I simply > > > guess, that the parport didn't run in EPP mode (or is not detected > > > correctly), please make sure to have it in EPP mode (check BIOS > > > settings), also check the options for the parport_pc modules (no > > > IRQ should be assigned)... > > > > Gerhard, > > > > Thanks for the suggestions. Sadly, it's still not working. Here's > > the complete debugging output from "scanimage -L". My apologies to > > the list for posting such a long message. > > > [SNIPSNAP] > > [plustek_pp] Assigning port handle 0 > > [plustek_pp] ptdrvOpen(port=0x0) > > [plustek_pp] Try to claim the parport > > [plustek_pp] Setting SPP-mode > > [plustek_pp] Setting PS/2-mode > > [plustek_pp] We're using libIEEE1284 I/O > > [plustek_pp] Starting Scanner-Autodetection > > Hmmm, did you really check your BIOS settings? Please make sure, that > NO ECP is enabled. You might try and set the port to SPP mode. Also > set the parport_pc modules parameter, i.e. > options parport_pc io=0x378 irq=none > This seems to be necessary on some boards, esp. with VIA chipset. Gerhard, No, sorry, I've tried every combination, and nothing works. I would be happy to try to debug this myself (and to send you a patch, if I could find one). Is there any way I can get hold of any documentation to understand the conversation between the PC and the scanner? John
