Hi,

On Friday 19 August 2005 18:24, Michael van Rooyen wrote:

> I posted the following to the sane-devel list.  I'm having difficulty
> getting an HP8200 scanner working.  Do you have any idea what might be
> wrong?

Try the latest sane release and/or my Subversion repository at:

  http://svn.exactcode.de/sane-avision/trunk/

Your sane version is too old.

Yours,

-- 
Ren? Rebe - Rubensstr. 64 - 12157 Berlin (Europe / Germany)
            http://www.exactcode.de | http://www.t2-project.org
            +49 (0)30  255 897 45
-------------- next part --------------
A non-text attachment was scrubbed...
Name: not available
Type: application/pgp-signature
Size: 189 bytes
Desc: not available
Url : 
http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20050819/351792de/attachment.pgp
From [email protected]  Fri Aug 19 19:44:24 2005
From: [email protected] (Pierre Willenbrock)
Date: Fri Aug 19 19:45:19 2005
Subject: [sane-devel] genesys backend
In-Reply-To: <877jehd9em.wl%[email protected]>
References: <[email protected]>     
<[email protected]>     
<[email protected]>
        <877jehd9em.wl%[email protected]>
Message-ID: <[email protected]>

Zhixing Xue schrieb:
> Hi Pierre,
> 
> thanks a lot for your work.
> I'm a owner of canon lide 35 scanner. I had got the experimental cvs and used 
> your patch.
> 
> With 'scanimage -L' I got:
> 
> device `genesys:libusb:001:002' is a Canon LiDE 35/50 flatbed scanner
> 
> But after first 'scanimage >image.pnm' both image.pnm and raw.pnm are black
> pics by me. And if I run 'scanimage >image.pnm' again, it stops there. I
> must unplug it and then plug it again, to get the black pic.
> 
> I didn't enabled debug mode jet, if you want more details, I'm glad to help.
> 
> xue
> 

Hi Zhixing, hi list,

as explained in my last mail, only color mode works currently. No
calibration yet. And quite some bugs are still left. scanning with
'scanimage --mode Color > image.pnm' should work, and result in a
colored image.pnm and a (more or less) grey raw.pnm, divided in three
columns(one per color).

I am glad to see it working that well, i feared more stuck scanning
heads, as happens here sometimes.

Currently i am splitting the register initialization in movement and
optical parts. This will hopefully lead to a unified way to initialize
the scanner for normal scanning as well as for calibration and ease
integration of other scanners. I will send another patch when i am
finished with that.

Regards,
  Pierre