Gerhard Jaeger schrieb: >>Here we go, one quick test. I start xscanimage as normal user. It >>doesn't ask me what device I want to choose (like it does for root), >>it uses the net:localhost:plustek_pp:parport0 automatically. I click >>"Preferences" in the menu and check the checkbox "Show advanced >>options": xscanimage disappears without saying "Good bye". > > > Hmmm, no very nice ;)
Mea culpa. I found the reason for the GUI-crashes this morning. When I see a file with a conf-extension, I cannot resist :-) My plustek_pp.conf contained the lines: |option warmup 10 |option lOffOnEnd 1 |option lampOff 30 The last line causes xsane & xscanimage to crash. The lamp switches off 30s after program start. Then the next mouse click kills the GUI. I could reproduce this several times. After changing back the last line to default value (-1) both programs run rock-solid. > Yep! Try > chmow a+rw /dev/.static/dev/parport0 I'll try. > So keep the masochism and try to compile SANE from source, install it > and see if the plustek_pp stuff works better. I will, but not on my current setup. I've seen the required versions of some libs to compile the current CVS source. I would have a lot of trouble on Debian Sarge with dependencies and don't want to break other applications. But I'll find a partition to install a distri with more recent packages. Best Regards Daniel