I think I found a bug in sane-canon: Using a CanoScan FS2710 on a Pentium, scanimage and xscanimage in raw mode gives endian inverted data (12 bits per color per pixel in pnm files).
Using imagemagick on the raw data give images with noise. Switching bytes before using imagemagick' convert works ok. The noise also appears in preview window when mode is raw, so the bug is probably in sane and not imagemagick. A small program performing endian-swicthing 2bytes/channel pnm files can be found at http://www.nirgal.com/kod/swappnm.c It may be usefull for debugging such problems in other cases. I use Debian sid i686 binary release: nirgal@zain:~$ scanimage -V scanimage (sane-backends) 1.0.17; backend version 1.0.17 nirgal@zain:~$ xscanimage -V xscanimage (sane-frontends) 1.0.14 Host: scsi0 Channel: 00 Id: 05 Lun: 00 Vendor: CANON Model: IX-27025E Rev: 1.13 Type: Scanner ANSI SCSI revision: 02 Images were scaned with: scanimage -v --resolution=2720 --mode Raw > image.pnm I'll have access to that hardware until December 31st.