Stef Thanks for prompt reply and thanks for the encouraging news. I was not looking forward to throwing out a perfectly good scanner!
Results of your suggestions: [root@localhost adrian]# export -p declare -x SANE_DEBUG_UMAX_PP="255" declare -x SANE_DEBUG_UMAX_PP_LOW="255" [root@localhost adrian]# export SANE_DEBUG_UMAX_PP=255 [root@localhost adrian]# [root@localhost adrian]# export SANE_DEBUG_UMAX_PP_LOW=255 [root@localhost adrian]# [root@localhost adrian]# scanimage -L [sanei_debug] Setting debug level of umax_pp to 255. [umax_pp] init: SANE_Auth_Callback not supported (yet) ... [umax_pp] init: SANE v1.0.18, backend v1.0.604-dev [umax_pp] init: evaluating option <option buffer 2097152> [umax_pp] init: option buffer 2097152 [umax_pp] init: option buffer 2097152 [umax_pp] init: setting global option buffer to 2097152 [umax_pp] init: don't know what to do with `device : /dev/parport0' [umax_pp] umax_pp_try_ports: trying port `/dev/parport0' [sanei_debug] Setting debug level of umax_pp_low to 255. [umax_pp_low] SANE_INB level 0 [umax_pp_low] sanei_umax_pp_InitPort(0x0,/dev/parport0) [umax_pp_low] parport modes: 47 [umax_pp_low] parport modes: PARPORT_MODE_EPP [umax_pp_low] umax_pp: ppdev couldn't negociate mode IEEE1284_MODE_EPP for '/dev/parport0' (ignored) [umax_pp_low] umax_pp: mode set to PARPORT_MODE_EPP for '/dev/parport0' [umax_pp_low] Using /dev/parport0 ... [umax_pp_low] status 120 doesn't match! umax_pp_low.c:5091 [umax_pp_low] No scanner detected by 'ringScanner(2,0)'... [umax_pp_low] status 120 doesn't match! umax_pp_low.c:5091 [umax_pp_low] No scanner detected by 'ringScanner(5,0)'... [umax_pp_low] status 120 doesn't match! umax_pp_low.c:5091 [umax_pp_low] No scanner detected by 'ringScanner(5,10000)'... [umax_pp_low] status 120 doesn't match! umax_pp_low.c:5091 [umax_pp_low] No scanner detected by 'ringScanner(5,10000)'... [umax_pp_low] No 1220P/2000P scanner detected by 'ringScanner()'... [umax_pp_low] ringScanner passed... [umax_pp_low] sendCommand(0x30) passed ... (umax_pp_low.c:7367) [umax_pp_low] sendCommand(0x00) passed... (umax_pp_low.c:7374) [umax_pp_low] status 126 doesn't match! umax_pp_low.c:5257 [umax_pp_low] testVersion(0) (umax_pp_low.c:7378) failed ... [umax_pp_low] testVersion(0) passed... [umax_pp_low] status 126 doesn't match! umax_pp_low.c:5257 [umax_pp_low] testVersion(1) failed (expected) ... (umax_pp_low.c:7385) [umax_pp_low] status 126 doesn't match! umax_pp_low.c:5257 [umax_pp_low] testVersion(0) (umax_pp_low.c:7394) failed ... [umax_pp_low] testVersion(0) passed... [umax_pp_low] status 126 doesn't match! umax_pp_low.c:5257 [umax_pp_low] testVersion(1) failed (expected) ... (umax_pp_low.c:7401) [umax_pp_low] sendCommand(0x40) passed... [umax_pp_low] sendCommand(0xE0) passed... [umax_pp_low] ClearRegister(0) passed... [umax_pp_low] SPPResetLPT() passed... [umax_pp_low] Found 0x77 expected 0xC7 (umax_pp_low.c:7474) [umax_pp_low] Trying 610p (umax_pp_low.c:7483) [umax_pp_low] sync610p failed (got 0x78 expected 0x38)! (umax_pp_low.c:3733) [umax_pp_low] sync610p failed! Scanner not present or powered off ... (umax_pp_low.c:6363) [umax_pp_low] initTransport610p() failed (umax_pp_low.c:6673) [umax_pp] attach: failed to probe scanner on /dev/parport0 [umax_pp] attach: couldn't attach to `/dev/parport0' (Error during device I/O) [umax_pp] umax_pp(v1.0.604-dev): line 254: debug exception [umax_pp] init: couldn't attach to port `/dev/parport0' [umax_pp] init: safe-auto attach failed ![umax_pp] init: don't know what to do with `astra 1220' [umax_pp] get_devices [umax_pp] unused arg: local_only = 0 No scanners were identified. If you were expecting something different, check that the scanner is plugged in, turned on and detected by the sane-find-scanner tool (if appropriate). Please read the documentation which came with this software (README, FAQ, manpages). [umax_pp] sane_exit: (...) Not sure what to make of the above . . . . Does it mean that parport0 is the incorrect address? Should I be using port 0x378 or port 0x38 Is safe-port auto more likely to work? What do you read? Adrian