stef <stef.dev at free.fr> wrote: Hi,
> Whenever a frontend built against SANE 1.0 receive one of the new > status, it > shows the error properly. Like SANE_STATUS_COVER_OPEN, JAMMED or NO_DOCS, in > case of SANE_STATUS_WARMING_UP user has to correct the error condition (in > this case just by waiting) before starting a new scan. When the error > condition is fixed (scanner is warm enough), the scan goes normally. I am worried this can break automated frontends in a semi-random way as it's possible with some hardware to get back a "warming up" status in a middle of a run. Although the frontends can be fixed pretty easily, it violates the principle of least surprise, and it's kind of a problem. JB. -- Julien BLACHE <http://www.jblache.org> <jb at jblache.org> GPG KeyID 0xF5D65169