Hello,
I have committed an update to the genesys backend which brings the
following
features for gl646 based scanners:
- shading calibration fix leading to much improved scan quality over
previous
releases.
- shading calibration for sheet-fed scanners, tested on the XP200.
Known bugs are:
- first scan after sheet-fed calibration doesn't load document properly.
- first scan with motor resolution is higher than max sensor resolution
is
black after calibration.
Regards,
Stef