Le mercredi 14 d?cembre 2011 10:17:38 K?re S?rs a ?crit :
> Hi,
>
> While testing the 16 bit features of Skanlite I noticed a problem with
> endianness. If I scan directly with epson2 on a x86 I get one byte order,
> but if I do a network scan through saned+epson2 running on a PowerPC I get
> the other order....
>
> Is there a workaround for this?
>
Hello,
does this byte inversion problem happen with any frontends ? Like
scanimage or xsane ? How epson2 running directly on PPC does behave ?
According to the SANE standard, the SANE_NET_START RPC sends the byte
order, which should allow to handle endianess issues.
Regards,