On Mon, Mar 10, 2014 at 6:17 PM, Rolf Bensch <rolf at bensch-online.de> wrote: > ADF paper empty detection is buggy for all MP150 based scanners. If you > like to help fixing this issue, please join this thread: > http://lists.alioth.debian.org/pipermail/sane-devel/2014-March/032138.html. > I cannot fix this by myself 'cause I have no ADF scanner.
Thanks for the pointer to that thread. By joining the thread, I assume you mean use the same subject. I will have a look at the code etc. in the near future. Meanwhile, I can confirm that the following, except for resolution 1200, works as expected (at least by first looks) on my USB-only-connected Pixma MX525, source flatbed: scanimage --resolution 75 > 75.pnm scanimage --resolution 150 > 150.pnm scanimage --resolution 300 > 300.pnm scanimage --resolution 600 > 600.pnm scanimage --resolution 1200 > 1200.pnm scanimage --mode color > color.pnm scanimage --mode gray > gray.pnm scanimage --mode lineart > lineart.pnm scanimage --gamma 0.7 > gamma.pnm scanimage --gamma 4 > gamma4.pnm scanimage -l 100 -t 50 -x 20 -y 20 > pos.pnm scanimage -l 100 -t 150 -x 20 -y 20 --resolution 1200 > 1200small.pnm scanimage --format tiff >x.tiff scanimage -p > x.pnm With resolution 1200, there seems to be some interlacing in the output. See http://flathen.net/tmp/75.pnm and http://flathen.net/tmp/1200.pnm.gz (287MB, 410MB unpacked) and http://flathen.net/tmp/1200small.pnm (You need the big one to see clearly.) -Trygve Some other outputs: $ scanimage -V scanimage (sane-backends) 1.0.25git; backend version 1.0.25 $ scanimage -L device `pixma:04A91769_12999B' is a CANON Canon PIXMA MX520 Series multi-function peripheral $ scanimage -A All options specific to device `pixma:04A91769_12999B': Scan mode: --resolution auto||75|150|300|600|1200dpi [75] Sets the resolution of the scanned image. --mode auto|Color|Gray|Lineart [Color] Selects the scan mode (e.g., lineart, monochrome, or color). --source Flatbed|Automatic Document Feeder [Flatbed] Selects the scan source (such as a document-feeder). Set source before mode and resolution. Resets mode and resolution to auto values. --button-controlled[=(yes|no)] [no] When enabled, scan process will not start immediately. To proceed, press "SCAN" button (for MP150) or "COLOR" button (for other models). To cancel, press "GRAY" button. Gamma: --custom-gamma[=(auto|yes|no)] [yes] Determines whether a builtin or a custom gamma-table should be used. --gamma-table auto|0..255,... Gamma-correction table. In color mode this option equally affects the red, green, and blue channels simultaneously (i.e., it is an intensity gamma table). --gamma auto|0.299988..5 [2.2] Changes intensity of midtones Geometry: -l auto|0..216.069mm [0] Top-left x position of scan area. -t auto|0..297.011mm [0] Top-left y position of scan area. -x auto|0..216.069mm [216.069] Width of scan-area. -y auto|0..297.011mm [297.011] Height of scan-area. Buttons: --button-update Update button state --button-1 <int> [0] [read-only] Button 1 --button-2 <int> [0] [read-only] Button 2 --original <int> [0] [read-only] Type of original to scan --target <int> [0] [read-only] Target operation type --scan-resolution <int> [0] [read-only] Scan resolution Extras: --threshold auto|0..100% (in steps of 1) [inactive] Select minimum-brightness to get a white point --threshold-curve auto|0..127 (in steps of 1) [inactive] Dynamic threshold curve, from light to dark, normally 50-65 $ scanimage -T scanimage: scanning image of size 638x877 pixels at 24 bits/pixel scanimage: acquiring RGB frame, 8 bits/sample scanimage: reading one scanline, 1914 bytes... PASS scanimage: reading one byte... PASS scanimage: stepped read, 2 bytes... PASS scanimage: stepped read, 4 bytes... PASS scanimage: stepped read, 8 bytes... PASS scanimage: stepped read, 16 bytes... PASS scanimage: stepped read, 32 bytes... PASS scanimage: stepped read, 64 bytes... PASS scanimage: stepped read, 128 bytes... PASS scanimage: stepped read, 256 bytes... PASS scanimage: stepped read, 512 bytes... PASS scanimage: stepped read, 1024 bytes... PASS scanimage: stepped read, 2048 bytes... PASS scanimage: stepped read, 2047 bytes... PASS scanimage: stepped read, 1023 bytes... PASS scanimage: stepped read, 511 bytes... PASS scanimage: stepped read, 255 bytes... PASS scanimage: stepped read, 127 bytes... PASS scanimage: stepped read, 63 bytes... PASS scanimage: stepped read, 31 bytes... PASS scanimage: stepped read, 15 bytes... PASS scanimage: stepped read, 7 bytes... PASS scanimage: stepped read, 3 bytes... PASS