* Julian Hauser <[email protected]> [May 31. 2017 15:15]: > On Wed, 31.05.17 14:39, Klaus Kaempf wrote: > > * Julian Hauser <[email protected]> [May 31. 2017 12:01]: > > > Great, that did it! The model number is 0x31. I've tried doing a test > > > scan but am getting an I/O error. > > > > Here's the log: https://pastebin.com/rr8j0gaN > > I've also tried scanning with pieusb debug on, here's the result: > https://pastebin.com/UrkjBX7j
You need to run through the scanner calibration once after every power-up of the scanner. You're trying to scan without calibration and the scanner complains with "Calibration disable not granted". Try with "xsane". Klaus -- SUSE Linux GmbH, GF: Felix Imendörffer, Jane Smithard, Graham Norton, HRB 21284 (AG Nürnberg) -- sane-devel mailing list: [email protected] http://lists.alioth.debian.org/cgi-bin/mailman/listinfo/sane-devel Unsubscribe: Send mail with subject "unsubscribe your_password" to [email protected]